MARPOL Annex I Regulation 12B (IBTS): preparing your bilge-water and OWS arrangements

Francis Wong
Francis Wong
Managing Director
"We are passionate about water conservation"

Direct answer: is MARPOL Regulation 12B in force yet?

Not yet. New MARPOL Annex I Regulation 12B, which would introduce the Oily Bilge Water Service Tank and allow controlled dewatering of oily bilge water by forced evaporation, is a draft that MEPC approved at MEPC 84 (27 April – 1 May 2026). Adoption is expected at MEPC 85 (30 November – 3 December 2026). It is not in force and does not change today's discharge rules under MARPOL Annex I Regulations 12–15, which remain the applicable requirement now.

Timeline with four milestones: PPR 13 February 2026, MEPC 84 approval April to May 2026, MEPC 85 adoption expected November to December 2026, entry into force not yet set.

What Regulation 12B proposes

Regulation 12B applies to ships of 400 gross tonnage and above that are fitted with an Integrated Bilge Water Treatment System (IBTS) — a system that separates and treats leaked oil and water to reduce bilge-water volumes. The regulation introduces the Oily Bilge Water Service Tank, used for the controlled dewatering of oily bilge water, including removal of water by forced evaporation: the water is heated so it evaporates, leaving oil behind for proper disposal.

Cutaway illustration of an IBTS service tank: oily bilge water in a steel upright tank, a heating coil at the bottom, water vapour rising off the surface and oil residue remaining below.

Scope and timing

  • Applies where an IBTS is installed on or after the date the regulation enters into force.
  • For ships with an IBTS installed before that date, the regulation is to be applied "as far as reasonable and practicable".
  • Consequential amendments cover the IOPP Certificate (Appendix II), the Oil Record Book (Appendix III) and revised guidance on recording operations in the Oil Record Book Part I.

What this means for ship owners now

Because Regulation 12B is draft, there is no compliance deadline to act on today — but it is a clear signal of where bilge-water handling is heading. While it is under discussion, the current rules still apply: ships over 400 GT need oily-water separation equipment meeting IMO MEPC.107(49), and oily water may only be discharged in accordance with MARPOL Annex I (notably the 15 ppm standard and area restrictions under Regulations 14 and 15).

For owners and managers preparing newbuilds or retrofit plans, the practical questions are about the bilge-water and OWS arrangement itself: which IBTS or separator is fitted, whether an oil residue (sludge) tank is correctly sized, and how retained oil is recorded and disposed of. These are exactly the questions a genuine-parts supplier helps you keep inspection-ready.

Numbered flow diagram of a bilge-water arrangement: service tank, two-stage oily water separator (coalescer then adsorber), 15 ppm monitor, overboard discharge and sludge tank.

Two-panel comparison: current rules with a 15 ppm oily water separator, and proposed Regulation 12B with an IBTS service tank using forced evaporation.

Keeping your OWS-type approval and parts genuine

Whatever the final text of Regulation 12B, one thing will not change: an oily water separator is only as compliant as the type-approved equipment and genuine parts installed in it. N&P Maritime (S.E.A.) Pte Ltd is RWO GmbH's Singapore partner since 2016 and supplies genuine RWO oily-water separator systems and spare parts on a supply-only basis. The RWO OWS-COM is designed to IMO MEPC.107(49), and we supply genuine coalescers, adsorber (polisher) candles, sensors and electrical parts with original RWO part numbers, so your arrangement retains its type-approval basis.

We are a supply company and do not provide onboard service or repairs; where a fleet already has RWO or Deckma equipment, we help identify the correct genuine spare part and confirm availability. Browse genuine RWO spare parts or review OWS-COM systems.

Conceptual illustration of genuine oily-water separator consumables: a coalescer filter element and a polisher (adsorber) candle beside an IOPP certificate and Oil Record Book.

Frequently asked questions

Has MARPOL Regulation 12B been adopted?

No. It was approved as a draft at MEPC 84 and adoption is expected at MEPC 85 on 30 November – 3 December 2026. Until adopted and in force, it is not a binding requirement.

Which ships will Regulation 12B apply to?

Ships of 400 gross tonnage and above fitted with an Integrated Bilge Water Treatment System (IBTS) installed on or after the regulation's entry into force. Ships with an IBTS already installed would generally apply it only as far as reasonable and practicable.

What is forced evaporation in bilge-water handling?

A process in which oily bilge water in the service tank is heated so the water evaporates, leaving the oil behind for proper disposal — the basis of the new Regulation 12B.

Does Regulation 12B change today's 15 ppm discharge rule?

No. It is a draft and not in force. The current MARPOL Annex I oily discharge requirements (including the 15 ppm standard and relevant area restrictions) remain the applicable rules.

Request a quote

Need to verify which genuine RWO OWS system or spare parts your bilge-water arrangement uses, or prepare for what is coming? Send us your equipment model, serial number or part number and we will confirm the correct genuine part and provide a quotation. Request a quote from N&P Maritime — replies within 1 business day.